GPS works with third-party, independent laboratories to continually strive for best-in-class indoor air testing. Tests are conducted in large chambers designed to simulate realistic applications. To learn more about test methodology, please request test reports.
These tests measure the reduction of certain airborne viruses and bacteria by aerosolizing a test specimen into a large biosafety test chamber (BSL2 or BSL3) and suspending it in the air using mixing fans.
Measurements of the specimen are taken at regular intervals and compared to a control without the introduction of ionization.
Microorganism |
Avg. Ion Density (ions/cc) |
Beginning Viral Concentration (TCID50/mL) |
% Net Reduction 30 Minutes |
% Net Reduction 60 Minutes |
Testing Laboratory |
SARS-CoV-2 | -3,500 | 9.97E+05 | 99.87% | NA | Innovative BioAnalysis |
SARS-CoV-2 | -4,900 | 9.63E+05 | 99.51% | NA | Innovative BioAnalysis |
Influenza A | -22,000 | 3.15E+07 | 43.32% | 99.78% | Innovative BioAnalysis |
Influenza B | -22,000 | 3.66E+06 | 36.21% | 85.44% | Innovative BioAnalysis |
RSV | -23,000 | 4.15E+06 | 35.85% | 97.06% | Innovative BioAnalysis |
Additional SARS-CoV-2 testing: | SARS-CoV-2 (12k ions) | SARS-CoV-2 (18k ions) | SARS-CoV-2 (Delta Variant) |
The GPS NPBI technology was tested by Innovative BioAnalysis in a 20 foot wide by 8 foot high by 8 foot deep chamber with a temperature range between 69 degrees and 77 degrees Fahrenheit and a relative humidity range between 42% and 52%. The technology was used in conjunction with an air handling unit designed to create and sustain achievable ion density levels that have been observed in real-world applications. Mixing fans were used to disperse the ions and suspend the test specimen within the chamber. Significant variations in temperature, humidity or other environmental factors may impact performance. Testing the reduction rate of any virus or bacteria with GPS NPBI technology is an ongoing process, and additional testing will continue in the future. Tests conducted in the same manner with attention to all experimental variables should come within a margin of error of the results stated above. These data points represent a subset of the full report. Please reference the full report for more details.
These tests measure the reduction of certain airborne viruses and bacteria by aerosolizing a test specimen into a large biosafety test chamber (BSL2 or BSL3) and suspending it in the air using mixing fans.
Measurements of the specimen are taken at regular intervals and compared to a control without the introduction of ionization.
Microorganism |
Fan Operating Speed |
Beginning Viral Concentration (TCID50/mL) |
% Net Reduction 10 Minutes |
% Net Reduction 20 Minutes |
Testing Laboratory |
SARS-CoV-2 |
High | 2.44E+06 | 51.27% | 96.71% | Innovative BioAnalysis |
Influenza A | High | 5.82E+06 | 39.63% | 96.08% | Innovative BioAnalysis |
The GPS NPBI technology was tested by Innovative BioAnalysis in a 22 foot wide by 11 foot high by 8 foot deep chamber with a temperature range between 68 degrees and 72 degrees Fahrenheit and a relative humidity range between 41% and 43%. The technology was used in a configuration as it would typically be installed. Mixing fans were used to suspend the test specimen within the chamber. Significant variations in temperature, humidity or other environmental factors may impact performance. Testing the reduction rate of any virus or bacteria with GPS NPBI technology is an ongoing process, and additional testing will continue in the future. Tests conducted in the same manner with attention to all experimental variables should come within a margin of error of the results stated above. These data points represent a subset of the full report. Please reference the full report for more details.
These tests measure the reduction of certain viruses and bacteria on surfaces by applying a specimen to glass slides, petri dishes or coupons and placing them on a table within a large biosafety test chamber (BSL2 or BSL3).
Measurements of the specimen are taken at regular intervals and compared to a control without the introduction of ionization.
Microorganism |
Avg. Ion Density (ions/cc) |
% Net Reduction 30 Minutes |
% Net Reduction 60 Minutes |
Testing Laboratory |
SARS-CoV-2 |
-9,700 | 55.50% | 62.85% | Innovative BioAnalysis |
-10,250 | 55.94% | 70.71% | ||
Staphylococcus aureus | -14,000 | 36.61% | 91.55% | Innovative BioAnalysis |
E.coli | -14,000 | 31.46% | 86.36% | Innovative BioAnalysis |
MRSA | -14,000 | 44.91% | 87.87% | Innovative BioAnalysis |
The GPS NPBI technology was tested by Innovative BioAnalysis in a 20 foot wide by 8 foot high by 8 foot deep chamber with a temperature range between 69 degrees and 77 degrees Fahrenheit and a relative humidity range between 42% and 52%. The technology was used in conjunction with an air handling unit designed to create and sustain achievable ion density levels that have been observed in real-world applications. Mixing fans were used to disperse the ions and suspend the test specimen within the chamber. Significant variations in temperature, humidity or other environmental factors may impact performance. Testing the reduction rate of any virus or bacteria with GPS NPBI technology is an ongoing process, and additional testing will continue in the future. Tests conducted in the same manner with attention to all experimental variables should come within a margin of error of the results stated above.
These test results demonstrate the additional reduction of particles in air when NPBI is combined with mechanical filtration versus filtration alone.
Particles from calibrated cigarettes were infused into a 10ft. x 10ft. x 10ft. chamber to provide a starting point consistent with wildfire smoke simulation.
Testing occurred at six air changes per hour (ACH), consistent with ASHRAE guidelines.
Change in Removal Rate1 of PM1.02 at 6 ACH (NPBI + MERV 8 vs. MERV 8 Alone) |
|
Test Duration in Hours3 | Average (12,060 ions/cc)4 |
1 | 2.26x |
2 | 2.11x |
NPBI + MERV 8 removed PM1.0 twice as fast as MERV 8 alone, the first two hours after particles were introduced, based on triplicate experiments5.
Change in Removal Rate1 of PM1.02 at 6 ACH (NPBI + MERV 10 vs. MERV 10 Alone) |
|
Test Duration in Hours3 | Average (10,640 ions/cc)4 |
0.5 | 1.51x |
1 | 1.56x |
NPBI + MERV 10 removed PM1.0 over 1.5 times faster than MERV 10 alone, the first hour after particles were introduced, based on triplicate experiments.
The GPS NPBI technology was tested by A2LA accredited [ISO 17025] Blue Heaven Technologies in a AHAM standard size testing chamber (10 ft. x 10 ft. x 10 ft.). The testing and chamber set-up follows ASHRAE 52.2 standards. The experiment design was based on industry standards and real-world scenarios. Consistent air pressure, temperature, and humidity was maintained throughout the test.
1. Removal Rate calculated as a 10-minute running average of reduction in PM1.0 per minute over the target time period. 2. PM1.0 is the mass concentration in μg/m3 of all particles with a diameter of less than 1.0 μm. 3. Measurement started after the first 15 minutes of testing to account for the high particle counts that result in unusually high average reduction in the first 15 minutes; agglomeration and surface deposition were highest during this period. 4. Ion density calculated as average of 30 minutes after reaching PM1.0 ≤ 35 μg/m3. This value was chosen as a proxy to ambient air based on EPA’s primary standard for supplemental health protection against short-term fine particle exposure which is a 24 hour outdoor average. (National Ambient Air Quality Standards (NAAQS) for PM | US EPA). 5. Product tested was the GPS-FC48-AC.
UL is the global safety science leader that provides testing, inspection and certification, including ozone safety standards that help people make informed choices when selecting systems.
All current GPS products* are certified to UL 2998 not to introduce more than five parts per billion of ozone - which is considered the threshold for zero ozone emissions.
For more information and to view our certified products, visit the Intertek Sustainability website.
UL Certification |
Standards |
Reports |
UL 2998 | Recommended by ASHRAE for consumers considering this type of technology |
PF-e |
PF-i | ||
IDF-2 | ||
DM-2 | ||
CI-2 | ||
GPS-DM48-AC | ||
GPS-FC48-AC | ||
GPS-FC24-AC | ||
GPS-FC-3-BAS |
||
GPS-iMOD |
||
GPS-iRIB-18/36 |
*Prior models may be either UL2998 certified or UL867 compliant.